▶Description
schneider ipsum dolor sit amet consectetur adipisicing elit. Ullam atque ducimus itaque voluptatem a minima, fugit obcaecati voluptates placeat asperiores dolorum eum corrupti doloremque impedit quaerat iusto consectetur esse cumque.
▶Specifications
Models: |
GV2ME01, GV2ME02, GV2ME03, GV2ME04, GV2ME05, GV2ME06, GV2ME07, GV2ME08, GV2ME10, GV2ME14, GV2ME16, GV2ME20, GV2ME21 |
Trip rating: |
(0.1...0.16 A),(0.16...0.25 A),(0.25...0.4 A),(0.4...0.63 A),(0.63...1.0 A),(1.0...1.6 A),(1.6...2.5 A),(2.5...4.0 A),(4.0...6.3 A),(6.0...10 A),(9...14 A),(13...18 A),(17...23 A) |
Trip unit technology: |
Thermal-magnetic |
Accessories: |
Auxiliary contacts (1N.O + 1N.C) |
▶Description
A complete motor protection concept
Manual motor starters, also known as motor protection circuit breakers (MPCBs) or manual motor protectors (MMPs), are electromechanical protection devices for the main circuit. They are mainly used to switch motors ON/OFF manually and to provide fuseless protection against short-circuit, overload and phase failures. Fuseless protection saves costs, space and ensures a quick reaction under short-circuit condition by switching the motor off within milliseconds. Starter combinations are setup together with contactors and are available with screw or Push-in Spring terminals.
▶Features
- Manual control / short-circuit current and overload protection
- Adjustable current setting for overload protection and magnetic trip indication
- Disconnection function
- Temperature compensation
- Short-circuit service breaking capacity Ics up to 100 kA.
▶Specifications
Models: |
MS132-0.16K, MS132-0.25K, MS132-0.4K, MS132-0.63K, MS132-1.0K, MS132-0.16K, MS132-1.6K, MS132-2.5K, MS132-4.0K, MS132-6.3K, MS132-10K, MS132-16K, MS132-20K, MS132-25K, MS132-32K |
setting range: |
(0.10...0.16 A), (0.16...0.25 A), (0.25...0.40 A), (0.40...0.63 A), (0.63...1.0 A), (1.0...1.6 A), (1.6...2.5 A), (2.5...4.0 A), (4.0...6.3 A), (6.3...10.0 A), (10.0...16.0 A), (16.0...20.0 A), (20.0...25.0 A), (25.0...32.0 A), |
Trip unit technology: |
Thermal-magnetic protection |
Accessories: |
Auxiliary contacts (1N.O + 1N.C),(2N.O + 2N.C) |
▶Description
Siemsn ipsum dolor sit amet consectetur adipisicing elit. Natus dicta quam, distinctio, modi dignissimos quaerat aliquam sint tempora assumenda quidem blanditiis, inventore labore. Corporis, obcaecati? Corporis fugit eius itaque voluptatum?
▶Specifications
Models: |
ST-10,ST-12,ST-20,ST-21,ST-25,ST-32,ST-35,ST-50,ST-65 |
Coil voltage: |
24v-50/60hz,110v-50/60hz,220v-50/60hz,380v-50/60hz |
Works with capacitor-banks: |
Yes (see manual for more information) |
Accessories: |
Auxiliary contacts (1N.O + 1N.C),(2N.O + 2N.C) |
▶Description
Manual Motor Starters Efficiency through various functions and compact design. Complete ranges up to 100A and 100kA Wide variety of accessories
▶Features
- 45mm for 32A, 55mm for 63A and 70mm for 100A
- Three position operator: ON-OFF-TRIP
- Complete range of common accessories
- Handle lock in the OFF position
- Class 10 overload trip characteristics
- Trip test available
- FDIN rail & Screw mounting
▶Specifications
Models: |
Refer to catalouge for detailed models |
trip range: |
Up to 100 A |
Trip unit technology: |
Thermal-magnetic trip |
Accessories: |
Auxiliary contacts (1N.O + 1N.C) |